When you have a wide area or venue to protect our wireless sensors can provide immediate alarm to a central control point for personal and portable sensor networks.
Ue the tabs below to select

MeshGuard is a rugged, battery-powered toxic gas detector integrated with a wireless mesh radio modem. MeshGuards can quickly be installed in hazardous locations, and remote readings are displayed on the FMC 2000 wireless controller. Automatic network configuration makes the MeshGuard a truly unique wireless solution for remote chemical detection in hazardous areas.
Key Features
- Mesh radio modem with automatic signal relay capability and 300m (1000 ft) communication between nodes
- Low power consumption with up to 6 months operation on replaceable battery
- Intrinsically safe C1D1, ATEX II 1G, IECEx Ex ia
- Designed for operation in extreme temperatures of -40° to 122° F (-40° to +50° C)
- Loud audio and bright visual alarms
- Large, easy-to-read continuous display of gas concentration in ppm
- Highly resistant to RFI and EMI
- IP-65 rated weather resistant, and splash guard equipped for sensor protection
- Small and lightweight, very fast to deploy
Applications
- Oil and gas drilling operations
- Oil and gas production
- Plant maintenance turnarounds
- Industrial safety
- Tank farms
- Shipyards and maritime
Sensor Specifications
|
Gas Monitor
|
Range |
Resolution |
Response Time T90 |
| Carbon Monoxide (CO) |
1-500 ppm |
1 ppm |
30 sec |
| Hydrogen Sulfide (H2S) |
0.1-100 ppm |
0.1 ppm |
20 sec |
| Flammables (LEL) |
0 to 100% LEL |
1% LEL |
15 sec |
| Sulfur Dioxide (SO2) |
0.1 to 20 ppm |
0.1 ppm |
30 sec |
Detector Specifications
| Size |
10.5" L x 3.7" W x 2.1" H (26.5cm x 9.5cm x 5.5cm) |
| Weight |
1.3 lbs (0.6kg) |
| Visual Alarm |
2 super-bright red LEDs |
| Audible Alarm |
90dB @ 30cm |
| Calibration |
Two-point field calibration |
| RF Frequency |
2.4GHz ISM Band, IEEE 802.15.4 standard compliant |
| Operating Range |
300 meters (line of sight) |
| Keypads |
Three operation and programming keys |
| Display |
Customized LCD (1" x 1.5" / 72mm x 108mm) with backlight |
| Power Supply |
Lithium Battery, +3.6V |
| Operation Time |
up to 6 months (Battery life will vary depending on Alarms conditions and temperature) |
| Operating Temperature |
-40° to 122° F (-40° to +50° C) for CO and H2S sensors |
| Humidity |
10% to 90% relative humidity, non-condensing |
| IP Rating |
IP-65 |
| Certifications |
- US and Canada: CID1, Groups A, B, C, D, T4
- Europe: ATEX II 1G Ex ia IIC T4
- IECEx Ex ia IIC T4
Contact manufacturer for country-specific certification
|
| RF Certifications |
FCC Part 15
CE
SRRC (Pending) |

The AreaRAE Steel is an ATEX-certified multi-gas, wireless monitor. Housed in a welded stainless-steel enclosure, it is rugged, portable and weather-resistant, making it suitable for harsh environments. Ideal for hazardous materials and other emergency response monitoring applications, strategically placed AreaRAE Steel monitors can be used to quickly establish a perimeter, allowing first responders to back off to a safe position and monitor readings from up to 3 kilometers away.
The photoionization detector (PID) in the AreaRAE Steel can measure parts per million of volatile organic compounds (VOCs). In addition, it can be equipped with a lower explosive limit (LEL) sensor, an oxygen sensor, and one or two electrochemical toxic sensors for measuring specific substances such as hydrogen sulfide or chlorine.
An integrated wireless modem transmits real-time gas measurement data to a base station, which employs a standard Windows-based PC running ProRAE Remote software. The base station can simultaneously control and display readings for up to eight AreaRAE Steels and/or AreaRAE Steel Gammas (or other AreaRAE-compatible monitors, including MultiRAE Plus, MiniRAE 2000, ppbRAE Plus, Smiths APD-2000®, BAE ChemSentry®, and Coastal Environmental Systems Weatherpak®). This provides a multi-threat detection network that can monitor a wide geographic area. Employing mesh networking capabilities, the AreaRAE Steel is designed for extended-range performance in difficult radio environments. The AreaRAE Steel is available individually or as part of the Rapid Deployment Kit (RDK) system package.

Key Features
- Up to five sensors (PID, LEL, O2 and two electrochemical toxic gas)
- Loud buzzer and large, extra-bright warning light
- Large LCD display and keypad
- Rugged, weather-resistant stainless-steel housing
- Built-in sampling pump
- Interchangeable Li-ion or alkaline battery pack
- Continuous operation via AC source
Advantages
- Real-time wireless data transmission with built-in RF modem
- View real-time sensor data and alarm status at headquarters or command center
- ProRAE Remote software simultaneously controls and displays readings for up to eight remote detectors
- License-free, 869MHz wireless transmission with communication range up to 3km
- Automatic mesh networking that allows each AreaRAE Steel to function as a repeater, greatly extending wireless range
- Optional wall-mounting bracket or field-mounting tripod adapter
Applications
- HazMat and Emergency Response
- Refineries and Petrochemical Plants
- Power Plants
- Pulp and Paper Industry
- Marine and Offshore Wells
Sensor Specifications
|
Gas Monitor
|
Range |
Resolution |
| Oxygen |
0-30.0% |
0.1% |
| Combustible |
0-100% LEL |
1% LEL |
| VOCs |
0-199 ppm
200-2000 ppm |
0.1 ppm
1 ppm |
| Carbon Monoxide |
0-500 ppm
10-2000 ppm |
1 ppm
10 ppm |
| Hydrogen Sulfide |
0-100 ppm |
1 ppm |
| Sulfur Dioxide |
0-20.0 ppm |
0.1 ppm |
| Nitric Oxide |
0-250 ppm |
1 ppm |
| Nitrogen Dioxide |
0-20.0 ppm |
0.1 ppm |
| Chlorine |
0-10.0 ppm |
0.1 ppm |
| Hydrogen Cyanide |
0-100 ppm |
1 ppm |
| Ammonia |
0-50 ppm |
1 ppm |
| Phosphine |
0-5.0 ppm |
0.1 ppm |
| Hydrogen Chloride |
2-15 ppm |
1 ppm |
| Hydrogen Fluoride |
2-10 ppm |
1 ppm |
Detector Specifications
| Size |
9.25" L x 5.0" W x 9.25" D (235mm L x 127mm W x 235mm D) without handle |
| Weight |
13.85 lbs (6.3 kg) with battery pack |
| Detector |
Up to five sensors (O2, combustible, two toxic and VOC), electrochemical sensors for toxic gases and oxygen, photoionization sensor for VOC, catalytic combustion sensor for combustible gases |
| Battery |
Rechargeable, 7.4V/4.5Ah, Lithium-ion battery pack with built-in charger (less than 10 hours charge time) or a 6 C-size alkaline battery pack |
| Operating Hours |
36 hrs continuous stand-alone operation
24 hrs continuous wireless operation (Lithium-ion battery)
18 hrs continuous wireless operation (alkaline battery) |
| Displays |
2-line, 16-digit LCD with manually activated LED back light |
| Keypads |
3 operation and 4 programming keys |
| Direct Readout |
Instantaneous values, sensor name, high and low values for all detectors, TWA and STEL values for toxic gases and VOCs, battery voltage and elapsed time |
| Alarm |
Flashing red LED cluster to indicate exceeded preset limits, low battery or sensor failure |
| Alarm Setting |
Separate alarm limit settings for TWA, STEL,Low and High alarm |
| Audible Alarm |
Buzzer, 100dB buzzer at 10cm (typical) |
| Visual Alarm |
Flashing red LED cluster |
| Alarm Mode |
Latching/automatic reset |
| Data Logging |
4,000 points for each sensor with time stamp, serial number, user ID, site ID |
| Data Storage |
20,000 readings (64 hours, 5 channels at 1 minute intervals) in non-volatile memory |
| Datalog Interval |
Programmable 1 to 3,600 sec |
| Communication |
Upload data to PC and Download monitor setup from PC through RS-232 link to serial port on PC |
| EM Immunity |
No effect when exposed to 0.43 mW/cm2 RF interference (5-watt transmitter at 30cm) |
| Safety Certification |
CSA Classified for use in Class I, Division 2, Groups A, B, C, and D (w/900 MHz modem) |
| Frequency |
902 to 928 MHz (License-free) |
| RF Range |
Up to 2 miles (900 MHz), extendable with RAELink2 Repeaters |
| Error Detection |
32 bit CRC, resend on error |
| Callibration |
Two-point field calibration for fresh air and standard reference gas |
| Sampling Pump |
Internal integrated diaphragm pump with programmable High (400cc/min) and Low (300cc/min) flow rate settings |
| Low Flow Alarm |
Auto shutoff pump at low-flow condition |
| Temperature |
-20° to 45° C (-4° to 113° F) |
| Humidity |
0% to 95% relative humidity (non-condensing) |
| Attachment |
Shoulder strap, optional tripod/wall mounting bracket |
| Optional |
Integrated GPS receiver |

The AreaRAE Gamma is a combination multi-gas and radiation detector equipped with a wireless, RF (radio-frequency)modem that allows the unit to communicate and transmit sensor and other information on a real-time basis with a remotely located base controller.
In the stand alone operation, the AreaRAE Gamma is a rugged, weather-resistant, one-to-five sensor portable monitor that can run up to 24 hours on either rechargeable Lithium-ion or optional alkaline batteries. It is also the first “lunchbox”- type multi-sensor instrument able to include a gamma sensor for measurement of gamma radiation, a photoionization detector (PID) for parts-per-million measurement of volatile organic compounds (VOCs), as well as an LEL combustible gas sensor, oxygen sensor, and a selectable electrochemical toxic sensor.
The RF modem allows real-time data transmissions with a base controller located up to two miles (3.2 km) away from the AreaRAE Gamma detector. A personal computer can be used as the base station. The standard ProRAE Remote software used to control AreaRAE Gamma systems is capable of monitoring the input of up to 32 remotely located monitors.

Key Features
- Up to four gas sensors (PID, LEL, O2 and selectable toxic gas)
- One radiation sensor (Gamma)
- Loud buzzer and large, extra-bright warning light
- Large LCD display and keypad
- Real-time wireless data transmission with built-in RF modem
- View real-time sensor data and alarm status at headquarters or command center
- License free, ISM band RF transmission with communication range up to 2 miles
- Fully hardware and software compatible with standard AreaRAE 5-gas monitoring system
- Standard AreaRAE is factory upgradeable to AreaRAE Gamma
- Rugged, weather-proof housing (IP55)
- Built-in sampling pump
- Interchangeable Li-ion or alkaline battery pack
- Continuous operation via AC source
Applications
- HazMat and Emergency Response
- Homeland Defense Applications
- Public Venue protection
- First Responders
- Port Security
- Border Crossings

ProRAE Remote is the PC based software that provides a simple Windows® user interface that integrates the outputs of up to 32 remote AreaRAE monitors into user-friendly displays. It also facilitates real-time, two-way wireless communication between AreaRAE and a base controller:
- Continuously displays sensor data from up to 32 AreaRAE units
- Shows alarm status when necessary with a single red light/green light display
- Can send alarms to cell phones and pagers
- Can communicate back to the remote sensor with text messages
- With GPS option, displays location of individual remote monitors on a geographic map
The RF modem allows real-time data transmissions with a base controller located up to two miles away from the AreaRAE detector. A personal computer can be used as the base station for an AreaRAE system. The standard ProRAE Remote software used to control AreaRAE systems is capable of monitoring the input of up to 32 remotely located monitors.

ProRAE Remote Includes:
- ProRAE Remote software CD
- Quick reference guide
- Operation and Maintenance manual
- RS-232 cable
- RAELink2 Remote unit modem, which includes a built-in rechargeable Lithium-ion battery, 120/240 VAC AC/DC adapter, and IEC - USG AC line cord
- 5dB antenna with magnetic mount and 12' of cable
- Hard transport case with pre-cut foam
The Rapid Deployment Kit (RDK) is designed for quick assessment and management of gaseous threats. The kit includes four wireless, 5-gas, AreaRAE monitors with in-case charging, and can be equipped with the Host Controller for monitoring from a command center up to two miles away. The system can scale up to 32 AreaRAEs with the addition of Detector Kits, each containing 4 AreaRAEs. The RDK offers first responders and environmental managers all detection tools they need in two rugged carrying cases.
The AreaRAE monitors can be rapidly deployed and re-deployed in situations that require a quick and adaptable response. They can be arranged in a perimeter to detect chemical hazards and to monitor the environmental safety of a large public event. The units help response teams gain control over potentially perilous situations by assessing the environment and determining the geographic disbursement of hazardous gases and chemicals. Housed in a military-grade self-contained case, the RDK is easy to transport and easy to deploy.
The RDK also provides protection in the monitoring of environmental remediation, oil, gas platforms, petrochemical applications, and refineries. The AreaRAE can detect gaseous VOCs, LEL, O2, H2S, and CO and offers datalogging for event documentation.
The RDK is also available with a global positioning satellite (GPS) option which includes the ability to track and display readings from up to 32 remotely located detectors on a GPS map.

Key Features
- In-case charging - One plug to charge 4 AreaRAEs and repeater in the case
- AreaRAEs stored with handles on for faster deployment
RDK Detector Kit Includes
- 4AreaRAEs
- RAELink2 repeater
- 4 spare Li-ion batteries
- External 4-bank battery charger
The Rapid Deployment Host Controller Kit (RDK) is designed for quick assessment and management of gaseous threats. The system can scale up to 32 AreaRAEs with the addition of Detector Kits, each containing 4 AreaRAEs. The RDK offers first responders and environmental managers all detection tools they need in two rugged carrying cases.
The AreaRAE monitors can be rapidly deployed and re-deployed in situations that require a quick and adaptable response. They can be arranged in a perimeter to detect chemical hazards and to monitor the environmental safety of a large public event. The units help response teams gain control over potentially perilous situations by assessing the environment and determining the geographic disbursement of hazardous gases and chemicals. Housed in a military-grade self-contained case, the RDK is easy to transport and easy to deploy.
The RDK also provides protection in the monitoring of environmental remediation, oil, gas platforms, petrochemical applications, and refineries. The AreaRAE can detect gaseous VOCs, LEL, O2, H2S, and CO and offers datalogging for event documentation.
The RDK is also available with a global positioning satellite (GPS) option which includes the ability to track and display readings from up to 32 remotely located detectors on a GPS map.

Key Features
- In-case charging - single external plug to charge both laptop and RF modem
- "Open the case" operation
RDK Host Controller Kit Includes
- Turn-key ProRAE Remote package in pelican case, including laptop and wireless modem

|

|
|
|  |
|