Environmental Dust, Radiation, Gas & Vapour Detection
Air Monitors are proud to distribute and support the wide range of Gas, VOC and Radiation monitoring technology from RAE Systems. We also offer a wide range of products from Thermo Fisher, BGI and Lighthouse for gases, vapours, particulate matter (dust) and aerosols.
A Range of Gas Detection Systems for Toxics, Combustibles, Oxygen and VOC's
The RAEGuard PID is a permanently mounted (fixed) volatile organic compound (VOC) monitor using a Photoionization Detector (PID) transmitter that operates from a 9 to 36 VDC power source and provides an analog (4-20 mA) signal output in three full scale ranges* of 20 ppm, 100 ppm, or 1,000 ppm isobutylene equivalent. Housed in an explosion-proof enclosure, the RAEGuard PID is equipped with a local digital display of the gas concentration and functional keys for performing calibration. Ranges 0-20, 0-100 and 1-1000 ppm (Isobutene equivalent - specify at time of order)
The RAEGuard EC is a permanently mounted (fixed) toxic gas or oxygen sensor/transmitter that operates from a 9 to 36 VDC power source and provides an analog (4 to 20mA) and digital (RS-485) signal output. Housed in an explosion-proof enclosure, the RAEGuard EC is equipped with a local digital display of the gas concentration and function keys for performing calibration. The RAEGuard EC is operated with a standard 4 to 20mA/RS-485 controller or as a stand-alone sensor module. Gases available are CO, H2S, SO2 and Oxygen.
The RAEGuard PID is a permanently mounted (fixed) volatile organic compound (VOC) monitor using a Photoionization Detector (PID) transmitter that operates from a 9 to 36 VDC power source and provides an analog (4-20 mA) signal output in three full scale ranges* of 20 ppm, 100 ppm, or 1,000 ppm isobutylene equivalent. Housed in an explosion-proof enclosure, the RAEGuard PID is equipped with a local digital display of the gas concentration and functional keys for performing calibration. Ranges 0-20, 0-100 and 1-1000 ppm (Isobutene equivalent - specify at time of order)
Portable Calibration Systems for Gas Detectors
AutoRAE is an auto-calibration, bump test and charging system for RAE Systems gas monitors. AutoRAE cradles are available for the QRAE, QRAE Plus, MultiRAE Plus, EntryRAE and MiniRAE 2000.
Press the button once for a bump test, twice for calibration, and walk away. A few minutes later, easy-to-read LEDs inform you of the status of the gas monitor’s sensors. If the monitor fails the bump test, the system automatically performs a calibration.
An optional external printer allows AutoRAE to print bump test and calibration certificates for record keeping.
Simple to operate, this PC-free version is highly portable. Consisting of one controller plus cradles, the system accommodates up to 10 cradles. It is easy to add cradles when the job demands it, and it is easy to add controllers, expanding one system into several systems.
Connecting the cradle to the controller or connecting cradles to each other is a snap. A single rigid mechanism containing all three throughputs (power, data, and gas) snaps one cradle to another. Simply place the monitor in a cradle (with the external filter on!) and the power, gas, and data ports of the gas monitor are all engaged.
Multi Gas Infra Red Monitor - Saphire
The MIRAN SapphIRe Series of Ambient Air Analyzers is the most versatile gas detection system on the market today.
The Analyzer's wavelength generator has a unique design that allows accurate and fast wavelength selection. This feature alone separates the MIRAN SapphIRe Analyzer from other gas analyzers.
The MIRAN SapphIRe Analyzer is available in three models with gas calibrations from one to over 100 gases. Any model can be easily upgraded to another model in the series, allowing you to economically meet both current requirements and future increased needs.
The MIRAN SapphIRe has the ability to identify unknown airborne compounds using the ThermoMatch software option. Designed with the needs of the industrial hygienist and emergency response community in mind, the analyzer can be brought to the incident resulting in quiker corrective action and less money expended on "blank" samples being analyzed at a lab.
All applications need to be examined and approved before an order will be accepted via the Completion of an Applications Feasibility Request.
Features
Easy to use
Selective
Sensitive for sub-ppm detection
Versatile and easily upgraded
Lightweight and portable
Multi Rae Gas Detection System
The MultiRAE IR combines a PID (Photoionization Detector) and Carbon Dioxide (CO2) sensor with O2, LEL, and one specific toxic gas sensor in one compact monitor with sampling pump. The MultiRAE IR’s versatility allows it to replace a wide range of monitors, saving training and maintenance costs. The MultiRAE IR is quickly and easily changed from a sophisticated technician instrument to a simple text or display only monitor. The same monitor can be used as a personal monitor, a hand-held sniffer or as a continuous, operational area monitor for use in applications such as indoor air quality and industrial hygiene.
Key Features
O2, LEL, PID, CO2, and any plug-in “smart” toxic sensors: CO, H2S, SO2, NO, NO2, Cl2, HCN, NH3, PH3
0-20,000 ppm measurement of CO2 using our patented non-dispersive infrared (NDIR) sensor
0-2,000 ppm measurement of VOCs (volatile organic compounds) with 0.1 ppm resolution
Measure more chemicals than with any other PID: With over 60 Correction Factors built into the MultiRAE IR memory and the largest printed list of Correction Factors in the world (300+), RAE Systems offers the ability to accurately measure more ionizable chemicals than any other PID!
Drop-in Battery: When work schedules require putting in more than the 12 hours supplied by the advanced Lithium-ion (Li-ion) battery, the drop in alkaline pack supplied with every MultiRAE IR allows you to finish the job.
User friendly screens make it easy to use for simple applications and flexible enough for sophisticated options.
Rugged Rubber Boot: The standard rubber boot helps assure that the MultiRAE IR survives the bumps and knocks of tough field use.
Strong, built-in sample pump draws up to 100’ (30m) horizontally or vertically. Liquid trap and automatic low flow alarm protect the MultiRAE IR from damage.
Large keys are operable even with 3 layers of gloves
Easy-to-read display with backlight
Store up to 80 hours of data at one minute interval for all 5 sensors for download to PC (with the optional datalogging).
Loud audible alarm that varies for different alarm conditions and an optional external vibration alarm for noisy areas