Ecotech Serinus Cal 2000

Ecotech Serinus Cal 2000

With all the features of its Serinus Cal 1000 stablemate, the Serinus Cal 2000 adds features essential for calibration of your NOx and O3 analysis equipment.

An internal ozone generator enables regular ozone checks and gas phase titrations (GPT).

Dilution Gas Inputs: 1 standard 100-200 kPa (g), (2 optional)

Source Gas Inputs: 4 standard 100-200 kPa (g), (8 optional)

Dilution Mass Flow Controller: 10 SLPM, 0 Deg, 1 ATM (std), 1 SLPM, 2 SLPM, 5 SLPM or 20 SLPM (optional), 2nd MFC (optional)

Source Mass Flow Controller: 50 SCCM, 0 Deg, 1 ATM (std), 10 SCCM, 20 SCCM, 100 SCCM, 500 SCCM or 1 SLPM, 2 SLPM (optional), 2nd MFC (optional)

Flow Accuracy (Constant Temp): Within 1% of full scale

Flow Repeatability: Within 0.15% of full scale

Linearity: Within 0.15% of full scale

Operating Gas Pressure: 100-200 kPa

Zero Drift: < 0.6% per year

Response Time: < 5 seconds

Output Manifold: 4 output ports standard

Dilution Ratio: Variable 10:1 to 2000:1 (std confi guration)

Output Concentration: 3 ppb to 5000 ppb

Flow Rate: Variable dependent on Dilution Mass Flow Controller installed

Repeatability: < 1% short term (24 hours) 5% long term at constant temperature and humidity

Operating Voltage: 100-240V VAC 50/60Hz (Auto Ranging)

Power Consumption: 165 VA maximum (typical at start-up for 3000) 95 VA after warm-up

Operating Conditions Ambient Temperature Range: 0°C-45°C (32°F-104°F), 20°C-35 °C >for optimum performance

Pressure:  Maximum altitude, 3000m above sea level

User Interface: Via front panel keypad or computer

Programmable calibrations: 16 separate programmable sequences 32 separate programmable points

Analog Output (3000 only): Voltage output of 0 to 5 V, with menu selectable zero o- set of 0%, 5% or 10%

Analog Input: Three analog voltage inputs (0-5VDC) CAT I rated

Digital Output: RS232 port #1: Normal digital communication, RS232 port #2: Multidrop port used for multiple analyser connections on a single RS232, USB port connection on rear panel, 25 pin connector with discrete status and user control, USB stick memory (front panel) for data logging, event logging and parameter storage. 8 Digital Outputs, open collector max 400mA each @ 12VDC (max total output 2A) 8 Digital Inputs, 0-5VDC, CAT I rated, 1 Diluent Control. +12V output

Case Dimensions: Rack length (front to rear): 597 mm (23.5”)

Total length (w/ latch release): 638 mm (25.1”)

Chassis width: 418 mm (16.5”)

Front panel width: 429 mm (16.9”)

Chassis height: 163 mm/uses 4RU (6.4”)

Front panel height: 175 mm (6.9”)

Serinus Cal 2000: 20.5 kg